Controls

The power switch and the XLR-input are located on the rear panel.

The monitor offers adjustment of important parameters on its front panel (see fig.)

Standby switches the monitor on and off. Please note that this switch does not separate
the monitor from the mains. The operating state is indicated by a LED that will be lit
green with the system ready to play, yellow if the monitor is turned off. With the rear
power switch turned off, no LED will light.

The monitor comprises a overload protection circuit. In case the input signal is too
high and therefore causes distortion, the circuit mutes the monitor to protect the
speakers. The red Overload-LED will blink as long as the protective action is active. The
maximum input level is reached when the Overload-LED starts blinking. Excessive use
of the monitor in this state will likely result in a reduced lifetime of the components. If
possible, turn down the source signal level.