Troubleshooting, Specifications – Panasonic Superdisk Drive Pack CF-VFS712 Benutzerhandbuch
Seite 8
Achtung! Der Text in diesem Dokument wurde automatisch erkannt. Um das ursprüngliche Dokument anzeigen, können Sie den "ursprünglichen Modus" verwenden können.

Troubleshooting
The computer does not recognize the
Superdisk Drive Pack.
The access lamp ([^) does not light.
Cannot read data from the disk.
Cannot eject the disk.
Is the Superdisk Drive Pack properly mounted
in the multimedia pocket?
Is the disk set correctly ?
Is the disk bent, scratched, or dirty?
Remove the check mark from [Auto insert
notification] and [DMA] under [StartJ-
[Settings]-(Control
Panel]-[System]-[Device
Manager]-[Disk
drives]-[MATSHITA
LS-
120 SLIM****]-[Settings]-[Options],
Is the computer powered on?
If not, power on and press the eject button.
<Use the following procedure if the previous method
failed.>
To remove a disk when the computer is powered off,
insert a sharp object such as a paper clip (made straight)
into the emergency hole. Pushing the object completely
to the end will enable the disk to be removed. However,
because there is the possibility that the lock mechanism
of the head carriage may not move, do not use this
method except for emergencies.
Emergency hole
Specifications
Item
Description
Operating Voltage Range
DC 5 V ±5%
Data Transfer Rate
531 to 958 KB/sec (120 MB mode)
221 (read), 74 (write) KB / sec (2HD mode)
111 (read), 37 (write) KB / sec (2DD mode)
Disk Rotation Rate
1440 rpm
Seek Time (Random seek)
65 ms (120 MB mode)
50 ms (2HD/2DD mode)
Interface
Conforms to enhanced IDE (ATAPI) standard
Dimensions (width x depth x height)
133.1 mm X 147.1 mm x 15.3 mm
(5.24 "x5.79 "x0.60 "}
Weight
Approx. 290 g [0.64 lb.}
Operating temperature / humidity range
5to35'’C (41 to 95 °F}*/30to 80% RH
(no condensation)
*15 minutes or more of consecutive disk access, using the SuperDisk Drive Pack be