Controls and indicators – Dynacord POWERSUB 315 Benutzerhandbuch

Seite 15

Advertising
background image

15

X-OVER

This switch lets you control the X-over frequency between subwoofer

and Mid-High-range satellite cabinets. The factory setting (100Hz)

is ideally suited for 12” satellite speaker systems. The 160Hz setting

matches top cabinets and protects the 10” or 8” transducers’ diaphragms

from mechanical overload. When employing top cabinets with 15”

speakers, the 80Hz position mostly provides improved sound.

SUB LEVEL

This control sets the volume of the PowerSub 315 in a setting range

between -∞dB to +10dB, while 0dB marks the center position.

Always adjust the PowerSub 315’s output level as precise as possible

and use the mixer’s bass controls for minor sound corrections only.

CONTROLS AND INDICATORS

SATELLITE SPEAKER OUTPUT

Outputs for the connection of satellite cabinets (e.g.

DYNACORD D 12). Each output provides a power

capacity of up to 500W into 4 ohms, offering the

possibility of connecting up to two 8 ohms satellite

speaker systems (e.g. DYNACORD D 12) per

output.

EXTERNAL SUB OUTPUT

This output socket is for the connection of up to

two additional passive subwoofers (e.g. one or two

DYNACORD SUB 115). Maximum output power of

the output is 500W into 4 ohms, when the MODE

SWITCH is set to ‘INTERNAL+EXTERN‘.

MODE SWITCH

When set to ‘INTERNAL SUB ONLY‘, only the

internal subwoofer is used and driven with 1000W /

8 ohms while the ‘EXTERNAL SUB OUTPUT‘ socket

is switched off.

When set to ‘INTERNAL+EXTERNAL‘, the

integrated power amps output power is distributed

between the internal and externally connected,

passive subwoofers. Compared to the ‘INTERNAL

SUB ONLY‘ setting and despite the fact of power-

output distribution, this setting provides a little bit

higher overall SPL because of the increase in the

total diaphragm surface and the lower mechanical

excursion of each diaphragm.

Advertising