Trouble shooting, Gb ie cy – Parkside PNTS 1300 B2 Benutzerhandbuch
Seite 11
Advertising

11
GB IE
CY
Trouble shooting
Problem
Possible cause
Fault correction
Device does not start
Mains voltage is not present
Check plug socket, cable, line,
plug and fuse, where appropri-
ate, repair through electrical
specialist
Defective on/off switch
(
3)
Repair through customer service
Worn carbon brushes
Defective motor
Low or lack of suction
Hose system (
13/14) or
jets (
18/19) blocked
Remove obstructions and block-
ages
Suction pipe (
12) assem-
bled incorrectly
Assemble suction pipe correctly
Container (
6) open
Close container
Container (
6) full
Empty container
Filter (
15/16/17) full or
clogged
Empty, clean or replace filter
Ball on filter basket (
24)
incorrectly positioned (e.g.
due to jerky movements)
Switch off the equipment so the
ball drops then switch on again
Advertising