10 troubleshooting, Error checklist – Sennheiser Sound Field System EMP 2015 Benutzerhandbuch
Seite 65

67
10 Troubleshooting
Error checklist
Problem
Possible cause
What to do
You hear whistling noise
ț
Microphone volume is adjusted
ț
Reduce the volume with the
too high
microphone volume control
No operation indication
ț
Battery is flat (transmitter)
ț
Replace the battery
ț
No mains connection (EMP 2015)
ț
Check to see if the mains plug is
connected and if the amplifier is
turned on
No RF signal and
ț
Transmitter and/or receiver section
ț
Turn the transmitter and/or
no audio signal
are turned off
receiver section on
ț
Transmission frequency is not the
ț
Set the transmitter and the
same as the receiving frequency
receiver section to the same
frequency
(
u “Special adjustments”)
ț
Transmitting antenna is not connected
ț
Connect the antenna
RF signal available but
ț
Transmitter is muted (“MUTE”)
ț
Deactivate the muting function
no audio signal
ț
Receiver section’s squelch threshold
ț
Adjust the squelch treshold to a
is adjusted too high
lower value (
u “Adjusting the
squelch threshold”)
ț
Microphone is not connected
ț
Connect the microphone
Speaker’s voice too soft
ț
Microphone volume is adjusted
ț
Increase the microphone
too low
sensitivity on the transmitter
or the microphone volume on
the EMP 2015
ț
Microphone is covered or
ț
Position the microphone at
positioned too far from the mouth
the corner of the mouth
Speaker’s voice too loud
ț
Microphone volume is adjusted
ț
Reduce the volume with the
too high
microphone volume control
Speaker’s voice distorted
ț
Transmitter sensitivity is adjusted
ț
Adjust the sensitivity to a lower
too high
value (
u “Adjusting the
sensitivity”)
ț
Receiver section’s AF output level is
ț
Reduce the volume with the
adjusted too high
microphone volume control
Volume of sound reproducing
ț
Volume at the line input is adjusted
ț
Reduce the volume of the
device adjusted too high
too high
audio device with the
corresponding volume control