Please tighten both screws when finished and re-check tracking force after adjusting VTA.
10. Azimuth adjustments are facilitated through the small allen screw on the bottom side of
the armwand where the headshell enters the carbon fibre. Once you loosen this screw,
you´ll be able to rotate the headshell a small amount in either direction. Be sure to tighten
the screw when done.
11. Listen to familiar recordings and make fine adjustments, as necessary, per cartridge
manufacturers instructions for best sound.
12. Please notice: Always move the mounted tonearm after you lift it up.
Attention:
Before the first use or after a long storage, please apply the lift unit up and down
approximately 4-5 times, so that the oil inside can dissolve in order that the lift unit can
move smoothly.
Picture 8: Screw one for VTA
adjustments
Picture 9: Screw two for VTA
adjustments
Picture 10: Allen screw on the bottom
side of the armwand