TrouBleshooTing
proBleM
possiBle Causes
whaT To Do
The Hot Water LED flashes
when the machine is turned
On
Hot Water dial is Open.
Turn the Hot Water dial to the
CLOSED position.
The Steam LED flashes when
the machine is turned On
Steam Lever is Open.
Move the Steam Lever to the
CLOSED position.
Water does not flow from
the group head
Machine has not reached
operating temperature.
Allow time for the machine
to reach operating tempera-
ture. The POWER light will
stop flashing when machine
is ready.
Water tank is empty.
Fill Tank.
Water tank not fully inserted
& locked.
Push water tank in fully and
lock latch closed.
FILL TANK On in LCD dis-
play, but water tank is full
Water tank is not fully
inserted and locked into
position.
Push water tank in fully and
lock latch closed.
No Steam or Hot Water
Machine is not turned on.
Ensure the machine is
plugged in, switched On
at the power outlet and the
POWER button is On.
No Hot Water
Water tank is empty.
Fill water tank.
No Steam
Steam Wand is blocked.
Use the pin on the cleaning
tool to clear the opening. If
the steam wand continues to
be blocked remove the tip
of the steam wand using the
spanner in the cleaning tool
and soak in hot water.
The machine is ‘On’ but
ceases to operate
Turn machine Off. Wait for
60 minutes and turn machi-
ne back On.
Steam pouring out of group
head
Turn machine Off. Wait for
60 minutes and turn machi-
ne back On.