8. Points to note
Waste fluid tank:
The waste fluid tank has a capacity of approx. 0.5 litres. We recommend regular draining of the tank,
to avoid any damage. Please note that with intensive use waste fluid can evaporate completely leaving
residue within the waste tank.
To empty the waste fluid tank:
1. On the back panel you will find the drain tube, which can be pulled out
(see Fig 2, No. 10, page 7).
2. Remove the sealing plug from the drain tube.
3. To empty the waste fluid tank completely, tilt the
Double Matrix Professional Sonic
about
45° to the rear. Once emptied, be sure to reseal the drain tube again.
CAUTION:
Do not re-use waste cleaning fluid. This could damage your machine.
Cleaning the fluid reservoir:
The cleaning fluid reservoir has a capacity of approx. 0.4 litres. We recommend that you fill the tank
only with Clearaudio Pure Groove cleaning fluid (available
cleaning results.
CAUTION
:
Never use foaming or corrosive liquids, or water. This could cause serious damage to your machine
and may void your warranty.
LED level indicator:
When the last LED (0%) of the level indicator is flashing (Fig. 2 No. 12, page 7), the functions “Auto”,
“Superclean” and in manual mode, the function “Liquid”, will be deactivated. This protects the liquid
pump from damage. To re-activate these functions, fill the cleaning fluid reservoir with more Pure
Groove cleaning fluid.
CAUTION:
Ensure that the
Double Matrix Professional Sonic
is switched on when filling the cleaning fluid reservoir
so that you can read the current level on the LED level indicator.
Fig. 5: Warning