Dynacord Digital Audio Matrix P 64 Benutzerhandbuch
Seite 26

Network configuration
26
P 64 Digital Audio Matrix
Owner’s manual
Example:
The following illustration shows an example application with four P 64 in a closed network. These
are networked with a PC via a central Ethernet switch. Thus, the factory preset IP address
192.168.1.100 would exist four times in the network. Because of this, the preset IP address of
three P 64s must be replaced with a unique address.
It is advantageous and strongly recommended to list all devices used in the Ethernet network and
IP addresses for changing the preset IP addresses of the P 64s. An example of such a list for the
example system shown in the above illustration is given in the following. You will find an empty
form in the appendix. Please enter the description of the device, an unambiguous description and
the IP address which has to be assigned to the device for every device used in the network in this
list. If the device is displayed in IRIS-Net, you can also use the description that is used there.
When the example system is put into operation, the IP addresses which are given in the overview
table, should be assigned to each device. The assignment of the IP address can be made via
IRIS-Net and via the P 64 browser interface. In IRIS-Net the assignment is possible both over the
USB interface and the Ethernet interface of the P 64. Information about the exact proceedings
are given in the IRIS-Net online-help. For the assignment of the IP address over the P 64
browser interface open the browser interface using the current (preset) IP address of the P 64.
Information about the exact proceedings are given in the P 64 browser manual.
Example of an Ethernet network with four P 64
Device
IRIS-Net Device Name
Location/Description
IP-Adresse
P 64
main office
main office
192.168.1.100
PC
-
main office
192.168.1.1
P 64
administration
administration building
192.168.1.101
P 64
production
production building
192.168.1.102
P 64
multi-purpose
mult-purpose hall
192.168.1.103