Sony SIR-3400H Benutzerhandbuch
Seite 124

17-12
(E)
SIR-3400H / SIR-3032i / SIR-3032W
Command
Contents
LVA?
Signal level readout (text format)
Command format
LVA? <1>/[ ]
<1>
: Measuring unit ID number (0=Recording unit)
Returned format
LVA : <1><2>...<32> during unidirectional (related to BAR command)
<1><2>
: CH 1 data (2-digit hexadecimal)
<31><32> : CH 16 data (2-digit hexadecimal)
7F=MAX and overload (OVR)
00=MIN
Returned format
LVA : <1><2>...<64> during bidirectional (related to BAR command)
<1><2>
: CH 1 MAX data (2-digit hexadecimal)
<3><4>
: CH 1 MIN data (2-digit hexadecimal)
<61><62> : CH 16 MAX data (2-digit hexadecimal)
<63><64> : CH 16 MIN data (2-digit hexadecimal)
7F=MAX and overload (OVR),
+100 % = 60
80=MIN and overload (OVR),
_100 % = A0
LVB?
Signal level readout (binary format)
Command format
LVB? <1>/[ ]
<1> : Measuring unit ID number (0=Recording unit)
Returned format
LVB : <1><2>...<16> during unidirectional (related to BAR command)
<1> : CH 1 data (binary)
<16> : CH 16 data (binary)
7F=MAX and overload (OVR)
00=MIN
Returned format
LVB : <1><2>...<32> during bidirectional (related to BAR command)
<1> : CH 1 MAX data
<2> : CH 1 MAX data
<31> : CH 16 MAX data
<32> : CH 16 MAX data
7F=MAX and overload (OVR)
80=MAX and overload (OVR)
MEM?
Recording memo readout
Command format
MEM? <1>/[ ]
<1> : 0=Recording unit setting data, 1=Recording media data
Returned format
MEM : <1><2>...<96>
<1><2>...<96>: Text characters up to maximum 96 characters
Related command : MEM
MOD?
Transport mode readout
Command format
MOD? /[ ]
Returned format
MOD : <1><2>
<1> : 0=STOP, 1=FWD, 2=E-E, 3=REC, 4=FWD-PAUSE, 5=REC-PAUSE, 6=FF,
7=RSV, 8=REW, 9=RSV, A=EJECT
<2> : S=During STOP transition
P=During PAUSE transition
0=The end of transition
F=During FWD Transition
Related command : MOD
.
.
.
.
.
.
.
.
.
.
.
.
17. Control by Telnet