Stereo with two Cardioids (e.g. ORTF, X/Y)

Fig. 9b
Necessary angle

ω and distance d between two cardioids depending on recording angle α

(s ee F ig. 9a and Table 1; s implified according to Michael Williams ). T he s ound s ources s hould
be within this area – when looking from the microphone.

Distance d between the microphones in cm

///// Unusable area

Angle

ω

between

the microphones

0

5

10

15

20

25

30

35

40

45

50 cm

180°

160°

140°

120°

100°

80°

60°

40°

20°

80°

100°

120°

140°

160°

180°

recording angle

α

d

ω

Recording angle

α and axis angle ω;

all sound sources should be located within the
recording angle

α.

stereo
main axis

Area to be recorded
(e.g. orchestra or band)

a

b

α

b/a

Table 3

This table is used to determine the
recording angle from the ratio b/a.

b/a

angle

α

0.54

30°

0.73

40°

0.93

50°

1.15

60°

1.40

70°

1.68

80°

2.0

90°

2.38

100°

3.46

120°

5.50

140°

11.3

160°

oo

180°

α