Yamaha CLP-511 Benutzerhandbuch
Seite 49

46
(5) XG Native Bulk Data (reception only)
Data format: [F0H] -> [43H] -> [0nH] -> [4CH] -> [aa] ->
[bb] -> [hh] -> [mm] -> [
ll
] -> [dd] ->...-> [cc]
-> [F7H]
F0
Exclusive status
43
YAMAHA ID
0n
When n is received n=0~F, whichever is received.
When n is transmitted n always=0.
4C
Model ID of XG
aa
ByteCount
bb
ByteCount
hh
Address High
mm
Address Mid
ll
Address Low
dd
Data
|
|
|
|
cc
Check sum
F7
End of Exclusive
For information about “Address” and “Byte Count” fields, refer to
attached tables.
In the attached tables “TOTAL SIZE” partitions a data series into
single bulk dumps. The “address” is the first byte of the bulk data.
The checksum value is set such that the sum of Byte Count, Ad-
dress, Data, and Checksum has value zero in its seven least
significant bits.
If too much bulk data is received at a time there is a chance of
error. The total data for a bulk dump should not exceed 512 bytes,
it is recommended that data be kept under 512 bytes with an
interval time of 120msec or more between 512 byte bulk.
(6) Clavinova MIDI Format
Data format: [F0H] -> [43H] -> [73H] -> [3BH] -> [yy] ->
[F7H]
F0
= Exclusive status
43H
= Yamaha ID
73H
= Clavinova ID
3BH
= CLP-411/511 ID
yy
= Substatus
yy
Information
02H
Internal MIDI clock
03H
External MIDI clock
06H
Bulk Data
* The bulk data follows 06H.
* When yy=2, 3 or Clavinova common ID (01H) is recog-
nized
as well as 3BH.
BULK DUMP FORMAT
F0H, 43H, 73H
nnH
(Product ID: CLP-411=42H,
CLP-511=43H)
06H
(Bulk ID)
05H
(Sequence data, Bulk Dump Format)
0xH, 0xH, 0xH, 0xH (Data length= xxxx bytes)
[BULK DATA]
(low, high........low, high)
[CHECK SUM (1byte)] = 0-sum (BULK DATA)
F7H
(7) Special Control
Data format: [F0H] -> [43H] -> [73H] -> [3BH] -> [11H] ->
[0nH] -> [cc] -> [vv] -> [F7H]
43H
= Yamaha ID
73H
= Clavinova ID
3BH
= CLP-411/511 ID
11H
= Clavinova special control
0nH
= Control MIDI change + channel number
cc
= Control number
vv
= Value
Control
0nH
ccH
dd
Split Point
Always 00
14H
14H : Split Key Number(CLP-511)
Metronome
Always 00
1BH
00H : off
01H : –
02H : 2/4
03H : 3/4
04H : 4/4
05H : 5/4
06H : 6/4
07H : No accent
Channel Detune
ch: 00-0F
43H
00H-7FH
Voice Reserve
ch: 00-0F
45H
00H : Reserve off
7FH : on
*1 When Volume, Expression is received for Reserve On, they will be
effective from the next Key On. Reserve Off is normal.
(8) Others
Data format: [F0H] -> [43H] -> [1nH] -> [27H] -> [30H] ->
[00H] -> [00H] -> [mmH] -> [llH] -> [ccH] -> [F7H]
Master Tuning (XG and last message priority) simultaneously changes the
pitch of all channels.
F0H
= Exclusive Status
43H
= Yamaha ID
1nH
= Transmission from n=CLP is always 0. 0-F is received.
27H
= Model ID of TG100
30H
= Sub ID
00H
=
00H
=
mmH
= Master Tune MSB
llH
= Master Tune LSB
ccH
= don’t care (under 7FH)
F7H
= End of Exclusive
MIDI Data Format/MIDI-Datenformat/Format des données MIDI/Formato de datos MIDI
<Table 1-1>
MIDI Parameter Change table ( SYSTEM )
Address (H)
Size (H)
Data (H)
Parameter
Description
Default value (H)
00 00 00
4
020C - 05F4(*1) MASTER TUNE
-50 - +50[cent]
00 04 00 00
01
1st bit 3 - 0
→
bit 15 - 12
400
02
2nd bit 3 - 0
→
bit 11 - 8
03
3rd bit 3 - 0
→
bit 7 - 4
4th bit 3 - 0
→
bit 3 - 0
04
1
00 - 7F
MASTER VOLUME
0 - 127
7F
05
1
—
—
06
1
34 - 4C(*2)
TRANSPOSE
-12 - +12[semitones]
40
7E
00
XG SYSTEM ON
00=XG sytem ON
7F
00
RESET ALL PARAMETERS
00=ON (receive only)
TOTAL SIZE
07
*1: Values lower than 020CH select -50 cents. Values higher than 05F4H select +50 cents.
*2: Values from 28 through 33 are interpreted as -12 through -1. Values from 4D through 58 are interpreted as +1 through +12.
<Table 1-2>
MIDI Parameter Change table ( EFFECT 1)
Refer to the “Effect MIDI Map” for a complete list of Reverb, Chorus and Variation type numbers.
Address (H)
Size (H)
Data (H)
Parameter
Description
Default value (H)
02 01 00
2
00-7F
REVERB TYPE MSB
Refer to Effect MIDI Map
01(=HALL1)
00-7F
REVERB TYPE LSB
00 : basic type
00
0C
1
00-7F
REVERB RETURN
-
∞
dB...0dB...+6dB(0...64...127)
40
TOTAL SIZE
0E
02 01 40
2
00-7F
VARIATION TYPE MSB
Refer to Effect MIDI Map
00(=Effect off)
00-7F
VARIATION TYPE LSB
00 : basic type
00
TOTAL SIZE
21