25

English

5. Installation IP-alarmmodul




















The IP alarm module is connected to the router and network.Then the configuration of network will be
made. The magnetic contact is installed on the door correctly.

5.1 How to set the network access

In default setting of IP alarm module, the automatic IP address assignment via DHCP is enabled. If the IP
alarm module detects no DHCP server, the IP address 192.168.0.200 (subnet mask 255.255.255.0) will be
set automatically.


Please set a fixed IP address on IP Alarmodul to prevent an IP address change when
voltage is lost.

For configuring the IP alarmmodul you need to connect it to a PC / laptop. The PC / laptop must be in the
same network area (192.168.0.x). To find the IP alarmmodule please run the searching tool “CASA10010-
Finder”. Now you can set the IP adress from the IP alarm module manually.

IP-adress configuration

In order to connect to the IP alarm module, type the IP address in the address bar of Microsoft Internet
Explorer. If the IP address is unknown, please use "CASA10010 Finder" to locate module in network.

Now you can configure the IP adress and the subnet
mask and find out serial number and software version.


The default username is admin and the password

Entrance