Activation Guardmode:
Enable this setting

Schedule EXT:
Set the schedule to EXT to set up the activation of the camera by remote control. The
virtual input 1 corresponds to the channel group 1 on the IP alarm module. The virtual output 1
corresponds to the output group 1 on the IP alarm module and is used for the feedback to the remote
control. Set the checkbox “Disable Virtual output 2” if at the second output group on the IP alarm modul a
signal device (e.g sirene,flashinglight) is connected and this output shall be reseted when deactivating the
device.


Sensor EXT:
Set the sensor to EXT to evaluate the alarm message on the virtual input 2. The virtual input
2 corresponds to the input channel group 2 onto IP alarm module (magnetic contact).

Verification Off: There will be no video verification.

Action: Set the recording in the camera. This can be either images or video clips. Select the checkbox
“SD” and select “Medium”.

You can setup other services for data storing such as e-mail, FTP and NAS. For more
details please read the instruction manual for TVIP41550.


The alarm record from the PIR network camera will only start if the schedule is active
(remote control) and an alarm signal at the virtual input 2 was triggered. (Magnetic contact).