CHAPTER 21 FPS-T1U I

2

C BUS INTERFACE OPTION

21.1 Introduction
The FPS-T1U rack provides access to the I

2

C Bus interface in each installed FPS1000/S unit via the rear

panel MOLEX female connector located at the rear panel. The Clock is connected to pin 2 and the Data
is connected to pin 1. The specifications of the I

2

C of the FPS1000/S power supplies are kept when they

are installed in the FPS-T1U rack. Refer to Chapter 7 for the specifications and all operating details.

Module “A”

Module “B”

Module “C”

A0

1

0

1

A1

1

1

0

A2

1

1

1

21.2 Addressing (A0, A1, A2).
The address line of the FPS1000/S units installed in the FPS-T1U rack are internally fixed
Refer to the following table for detailes:

Note: Address are applicable when modules FPS1000/S (I2C option) are used

CAUTION

The I

2

C bus address lines, serial clock and data are

referenced to the -Sense potential. When using series

connection of FPS-T1U racks, do not connect the

I

2

C lines of the units together.

FPS-T1U Instruction Manual