Note!

Do not forget to connect the protective circuit to a clamp of the connection strip marked

with sign. The plate power supply system should be protected by appropriately

selected safety device or after the power supply protection, by appropriate safety

switch cutting off the power in case of emergency.

NSTALLATION

Connecting the plate to the electrical system

Note!

The plate can be connected to the mains only by a qualified certified installer. Wilful

adaptations or modifications to the electric system are prohibited.

Guidelines for the installer

The plate is provided with a terminal box enabling selection of proper connections for the

given type of power supply.

The terminal box enables the following types of connection:

- one-phase 230 V -

- two-phase 400 V 2N~

The plate can be connected to the appropriate power supply by adequate bridging on the

connection strip, in accordance with the attached wiring diagram. The wiring diagram is also

provided in the bottom part of the lower cover. The connection strip can be accessed once

the cover on the terminal box is removed. Please remember to match the mains connection

cable to the type of connection and the rated power of the plate.

Before connecting the plate to the electric system read information provided on the rating

plate and wiring diagram.

Note! The installer is obliged to complete and leave with the user a “certificate of connect-

ing the plate to the mains” (attached to the warranty card).

Methods of connection other than those indicated on the diagram can damage the plate.