Operation, Residual temperature indicator, Limited time of operation – AMICA KMI 13290 F DE Benutzerhandbuch

Seite 55

Advertising
background image

55

OPERATION

Residual temperature indicator

When a hot plate has been switched off letter “H” is displayed indicating that the hotplate is

still hot.

Do not touch the hotplate or put

heat-sensitive objects on it when

the “H” letter is displayed as you

can burn yourself or the object!

If the indication goes out you can touch the

hotplate but have to bear in mind that it still

does not have ambient temperature.

Residual heat indicator is off if the

power is off.

Limited time of operation

To increase its reliability the plate is pro-

vided with an operation time limiter for each

hotplate. The maximal times of operation

depend on the last selected heating power

level. A hotplate switches off automatically

if the heating power has not been changed

during the specified time (see the Table) and

the residual time indicator is lighted. You can

however switch on and use the respective

hotplates in accordance with the Operating

Manual.

Heating power

level

Maximal time of

operation in hours

2

1

6

2

6

3

5

4

5

5

4

6

1,5

7

1,5

8

1,5

9

1,5

P

0,16