Nstallation, Diagram of possible connections – AMICA KMI 13290 F DE Benutzerhandbuch

Seite 46

Advertising
background image

46

NSTALLATION

DIAGRAM OF POSSIBLE CONNECTIONS

Warning! Heating elements voltage - 230V

Recom-

mended

type of

connector

cable

1 For 230 V power supply, single

phase connection with a neutral

lead, 1-2 and 4-5 terminals are

shorted together, neutral lead

connected to 4, PE (protective

earth) lead connected to

1N~

H05VV-

F3G4

2 For 400/230 V power supply,

2-phase connection with a neutral

lead, 4-5 terminals are shorted

together, neutral lead connected

to 4, PE (protective earth) lead

connected to

2N~

H05VV-

F4G2,5

L1=R, L2=S, N=neutral lead terminal, =PE lead terminal

Warning! In every type of connec-

tion protective grounding has to be

connected to terminal.

4

5

L2 L1

PE

N

N

3

2

1

3

2

5

4

PE

N

1

L1

3

2

5

4

PE

L2

N

1