Seite 57 – Yamaha P-90 Benutzerhandbuch
Seite 57

P-90
57
4. PROGRAM CHANGE
Data format: [CnH] -> [ppH]
CnH = Program event (n = channel number)
ppH = Program change number
P.C.#=Program Change number
• When program change reception is turned OFF in the Func-
tion mode, no program change data is transmitted or
received. Also, Bank MSB/LSB is not transmitted or received.
5. SYSTEM REALTIME MESSAGES
[rrH]
F8H: Timing clock
FAH: Start
FCH: Stop
FEH: Active sensing
• Caution: If an error occurs during MIDI reception, the Damper,
Sostenuto, and Soft effects for all channels are turned off and
an All Note Off occurs.
6. SYSTEM EXCLUSIVE MESSAGES
(Yamaha MIDI Format)
Panel Data Transmit
Data format: [F0H] -> [43H] -> [0nH] -> [7CH] -> ... -> [F7H]
F0H, 43H, 0nH, 7CH (n: channel number)
00H, 2BH (data length)
43H, 4CH, 20H, 20H (CL)
43H, 4CH, 50H, 27H, 30H, 33H (CLP’03)
30H, 30H (version x, y)
[PANEL DATA]
[CHECK SUM (1byte)] = 0-(43H+4CH+20H+......+Data end)
F7H
• Panel Data Contents
• Panel data send requests cannot be received.
7. SYSTEM EXCLUSIVE MESSAGES
(Universal System Exclusive)
(1) Universal Realtime Message
Data format: [F0H] -> [7FH] -> [XnH] -> [04H] -> [01H] ->
[llH] -> [mmH] -> [F7H]
MIDI Master Volume
• Simultaneously changes the volume of all channels.
• When a MIDI master volume message is received, the volume
only has affect on the MIDI receive channel, not the panel
master volume.
F0H = Exclusive status
7FH = Universal Realtime
7FH = ID of target device
04H = Sub-ID #1=Device Control Message
01H = Sub-ID #2=Master Volume
ll
H =
Volume LSB
mmH =
Volume MSB
F7H = End of Exclusive
or
F0H = Exclusive status
7FH = Universal Realtime
XnH = When n is received n=0~F, whichever is received.
X = don’t care
04H = Sub-ID #1=Device Control Message
01H = Sub-ID #2=Master Volume
ll
H =
Volume LSB
mmH =
Volume MSB
F7H = End of Exclusive
Printed on the
panel
[VARIATION]
button
Voice Name
MSB
(0-127)
LSB
(0-127)
P.C#
(1-128)
GRANDPIANO 1
OFF
GrandPiano1
0
122
1
ON
(Variation)
0
123
1
GRANDPIANO 2
OFF
GrandPiano2
0
112
1
ON
(Variation)
0
112
2
E.PIANO1
OFF
E.Piano1
0
122
6
ON
(Variation)
0
122
89
E.PIANO2
OFF
E.Piano2
0
122
5
ON
(Variation)
0
123
5
CLAVI./HARPSI.
OFF
Clavi.
0
122
8
ON
Harpsichord
0
122
7
VIBES/GUITAR
OFF
Vibraphone
0
122
12
ON
NylonGuitar
0
122
25
CHURCH
ORGAN
OFF
ChurchOrgan
0
123
20
ON
(Variation)
0
122
20
JAZZ ORGAN
OFF
JazzOrgan
0
122
17
ON
(Variation)
0
123
17
STRINGS
OFF
Strings
0
122
49
ON
SlowStrings
0
122
50
CHOIR
OFF
Choir
0
122
53
ON
SlowChoir
0
123
53
WOOD BASS
OFF
WoodBass
0
122
33
ON
(Variation)
0
124
33
E.BASS
OFF
E.Bass
0
122
34
ON
(Variation)
0
122
36
Data
Transmission
Reception
F8H
Transmitted every
96 clocks
Received as 96-clock tempo timing
when MIDI clock is set to External
FAH
Recorder start
Recorder start
Not received when the MIDI clock is
set to Internal.
FCH
Recorder stop
Recorder stop
Not received when the MIDI clock is
set to Internal.
FEH
Transmitted every
200 milliseconds
If a signal is not received via MIDI for
more than 400 milliseconds, the same
processing will take place for All
Sound Off, All Notes Off and Reset All
Controllers as when those signals are
received.
(1) 1'st Voice
(2) Dual On/Off
(3) Dual Voice
(4) Dual Balance
(5) Dual Detune
(6) Dual Voice1 Octave
(7) Dual Voice2 Octave
(8) Dual Voice1 Effect Depth
(9) Dual Voice2 Effect Depth
(10) Split On/Off
(11) Split Voice
(12) Split Point
(13) Split Balance
(14) Split Voice1 Octave
(15) Split Voice2 Octave
(16) Split Voice1 Effect Depth
(17) Split Voice2 Effect Depth
(18) Split Dumper Mode
(19) Reverb Type 1
(20) Reverb Type 2
(21) Reverb Depth 1
(22) Reverb Depth 2
(23) Effect Type 1
(24) Effect Type 2
(25) Effect Depth
(26) Variation On/Off
(27) Touch Sensitivity
(28) Fixed Data
(29) Absolute tempo low byte
(30) Absolute tempo high byte
(31) Key-Off Sampling Depth