Baumer BA OADM20x659x Benutzerhandbuch

Seite 38

Advertising
background image

Manual_OADM20x659_DE_EN.doc

38/48

Baumer

04.12.12

Frauenfeld, Switzerland

5.2 How to reset the factory settings using the teach button

Within 5 minutes after power up, the button may be used to reset the sensor back to the factory settings.
After finishing a teach procedure

,

the 5 minutes starts again. After the 5 minutes, the sensor does not

respond to the button.

1. Push the button. The red LED will turn on, if the sensor can be taught.
2. Hold down the button further 5 sec. The LED will start to blink. DO NOT RELEASE the button now. Wait

another 10 sec until the LED is ON without blinking. Factory settings have been restored to the sensor.

3. Release the button.



5.3 How to teach a new range using the external teach input

Teaching the sensor via the external teach input is equivalent to the teaching procedure via the button. There
is no 5 min. time limit. The sensor may be taught at any time. In addition to the LED, the alarm output is used
to indicate the state of the sensor for an external digital controller.


t

Red LED

t1

t2

t3

t4

0 V

12-28 V

Teach wire

t7

t8

t9

Alarm

t6

t10

t6

t1

Red LED

t12

Until button has been

released (t13)

Advertising