Baumer BA OADM20x659x Benutzerhandbuch

Seite 40

Advertising
background image

Manual_OADM20x659_DE_EN.doc

40/48

Baumer

04.12.12

Frauenfeld, Switzerland

Time Description of timing functions

Value

Comment

t1

Minimum button hold time to enter
teach mode

5 s

Using the button, this feature can only be used
within 5 minutes after power-up. Using the
external teach input, it may be used at any
time.

t2

Maximum waiting time after teaching
the first position.

< 60 s

If the button has not been pushed during this
interval, the sensor will leave the teach mode
without any changes.

t3

LED on as response for the first
position.

approx 3 s

t4

Maximum waiting time after teaching
the second position.

< 60 s

If the button has not been pushed during this
interval, the sensor will leave the teach mode
without any changes.

t6

LED Blinking for “NOT OK response”
after teaching the second position.

approx 5 s

t7

Minimal time between high/low
transition of alarm output high/low
transition of the external teach input
at the beginning of the teach.

1 ms

t8

Pulse lengths on external teach input

for first position.

30..2000 ms

t9

Pulse lengths on external teach input

for second position.

30..2000 ms

t10

Delays between teach signal and
response on alarm output at the
rising edge of the signal.

< 20 ms

t11

Delay between teach signal and
response on alarm output at the
falling edge of the signal

< 10 ms

t12

Minimum blinking time for the reset
to factory settings with button.

10 s

t13

Blinking time after reset to factory
settings

> 0.2 s

As long as the button is down or the external
teach input is high.

t14

Minimum blinking time for the reset
to factory settings with external
teach input.

10 s

t15

Minimum high time of the external
teach input after the alarm output
has been set at the end of the
setting of the factory settings.

0.2 s

Advertising