Baumer BA OADM20x659x Benutzerhandbuch

Seite 39

Advertising
background image

Manual_OADM20x659_DE_EN.doc

39/48

Baumer

04.12.12

Frauenfeld, Switzerland

Delay between teach signal and response on alarm output:


Input circuit:



5.4 How to reset the factory settings using the external teach input

Teaching the sensor via the external teach input is equivalent to the teaching procedure via the button. There
is no 5 min. time limit. The sensor may be taught at any time. The alarm output can be used as an
acknowledge signal for a control system.


Delay between teach signal and response on alarm output:

t10

t11

alarm output

external teach input

27k

10k

teach-in

low: 0 .. 2V

high: 12 .. 28V

3V3

t11

alarm output

external teach input

0 V

12-28 V

red LED

Alarm output

Teach-in wire

t1

t14

t15

Advertising