8 Technical data


OADM 20I…

…6591

…6592

…6593

Measuring range MR

50…300 mm

100…600 mm

200… 1000 mm

Min Teach-in range

5 mm

10 mm

20 mm

Resolution *

1)

0.01…0.4 mm

0.015…0.8 mm

0.12…3 mm

Linearity error *

2)

±

0.2…

±

1.5 mm

±

0.5…

±

3.4 mm

±

0.36…

±

9mm

Response time *

3)

< 2 ms

< 2.5 ms

< 3.5 ms

Ambient light *

4)

100 kLux

100 kLux

60 kLux

Typ. Temperature coefficient *

5)

±

0.03%

MD/°C

±

0.03%

MD/°C

±

0.05%

MD/°C

Light source

Red laser diode, pulsed

Laser class

2

Wave length

650 nm

Laser line*

7)

high

width

6…11 mm

2 mm

7…17 mm

2 mm

8…25 mm

3…1 mm

Analog output

4 … 20 mA und 0 … 10 V

Load resistor U

Out

> 100 k

Load resistor I

Out

< (+Vs – 6 V) / 0.02 A

Alarm output

PNP / max. 100 mA

Voltage supply range

12 ... 28 VDC

Supply current

< 100 mA, (bei + 24V ~ 40mA)

Reverse polarity protection

yes, Vs to GND

Short circuit protection

Yes

Housing material

die-cast zinc

Tightening torque

1.0 Nm

Protection class

IP 67

Temperature range

- 20°C…+ 60°C

Storage temperature

- 20°C...+ 70°C

vibrations stability

IEC 60068-2-6

(30 g, 10-2000 Hz, per axis)

random stability

IEC 60068-2-64

(0,4 g2/Hz, 20-1000 Hz per axis)

bump stability

IEC 60068-2-29

(75 g, 6 ms, 4000 pulse per axis and direction)

Fault suppression

If the laser beam is interrupted or if measurement faults occur, the analog outputs and the

alarm output remain at their most recent valid value for a max. of 300 ms. Every valid value

is immediately passed on to the outputs. If no valid value appears within 300 ms, the analog

outputs switch to 4 mA / 0 V and the alarm output goes to HIGH.