13 Troubleshooting

Error

Possible reason

Correction

The sensor does not
measure

The sync. input or the teach-in
wire is connected to +Vs

Connect sync. input or the teach-in wire to 0 V

The receiving beam is covered by
an object / edge / step

Make sure that no object is in the receiving
field

No receiving signal (transparent or
highly reflective object)

Make sure that the laser spot falls on a diffuse
reflecting surface

The sensor has
incorrect measuring
values

Mutual optical interferences
between two or more sensors

Make sure that no other light spot is within the
receiving field of the sensor

Strong ambient light.

Prevent ambient light with a shield

Semi transparent, transparent or
highly reflective objects

Make sure that the laser spot falls on a diffuse
reflecting surface

The sensor does not
reach the accuracy

Rough surface

Possibly use a sensor with laser line

Color edges

Mount the sensor the correct way

Resolution of the A/D converter in
the control unit

Read the manual of the control unit