Baumer BA OADM20x659x Benutzerhandbuch

Seite 43

Advertising
background image

Manual_OADM20x659_DE_EN.doc

43/48

Baumer

04.12.12

Frauenfeld, Switzerland

Sensor

t1

t2

OADM 20I6591

< 2 ms

1.5 ... 6 ms

OADM 20I6592

< 2.5 ms

1.5 ... 7.5 ms

OADM 20I6593

< 3.5 ms

1.5 ... 10.5 ms


t1 is the max. time after a high signal on the synch. input of S1 until the analog value will be held. This value
will be held as long the signal on the synch. input is high.
The min. time between the high signal of S1 and the low signal of S2 is t1, also. In this case, an optical
influence between the sensors is not possible.
t2 is the time until the analog signal is ready after a low signal on the synch. input of S2. This time depends
on the reflectivity of the object and if the reflectivity changes during the hold time.


Input circuit








27k

10k

sync in

low: 0 .. 2V

high: 12 .. 28V

3V3