10 Grounding concept

For maximum EMC protection and reliable application, use a shielded cable. Also, the sensor has to be
grounded.
We recommend the grounding concept as shown in the picture. Ground the sensor with a toothed washer
between the screw head and the sensor.


If you prefer another grounding concept please contact your Baumer electric sales staff.


11 Service notes


The OADM requires no maintenance apart from keeping the front windows clean. Dust or fingerprints can
impair the sensor function. It is normally sufficient to wipe the windows dry with a clean (!), soft cloth. Alcohol
or soapy water may be used for heavy soiling.

12 Accessories


Mounting bracket

part no. 10131521



Protective cover

part no. 10156878, material is acrylic glass (PMMA)

The protection cover can be easily mounted on the sensor’s face. It protects the
glass front cover against welding splashes.