4.2 Pneumatic
• Remove the sealing elements from the compressed air ports.
• Attach the pneumatic tubing to the following connections (position of the con-

nections

Fig. 1):

– Compressed air supply port

1

– Air supply port

2

• Screw a silencer (accessories

www.festo.com/catalogue) into the exhaust

port

3.

4.3 Electric

Warning

• Use only PELV

circuits in accordance with IEC/DIN EN 60204-1 (protective

extra-low voltage, PELV) for the electrical power supply.

• Also observe the general requirements for PELV circuits in accordance with

IEC/DIN EN 60204-1.

• Use only

power sources that guarantee safe electrical isolation of the operat-

ing voltage in accordance with IEC/DIN EN 60204-1.

• Note the rating plate.

A distinction is made between the following valve variants (

Fig. 5).

Designation on the rat-
ing plate

MPPE-...-010B

MPPE-...-420B

Designation

Voltage variant

Current variant

Electrical setpoint value

DC 0 ... 10 V

4 ... 20 mA

Fig. 5

Note

• Check the use of the following options on the MPPE-3-... :

– Reference voltage V

ref

of DC 10 V on the valve

– Scanning an external pressure sensor
– Measuring the actual voltage/current value

• Use the following accessories (accessories

www.festo.com/catalogue):

– Socket with cable or
– Plug socket and
– shielded cable.
You can then guarantee that the specified protection clss IP 65 and EMC are
fulfilled.

• Wire the screening with earth potential at the cable end away from the MPPE.

Note

Make sure that the cable is laid as follows:
– not squashed
– not bent
– not stretched

Fig. 6

• Wire the MPPE-... according to one of the connection diagrams:

Voltage variant with external set
value voltage

Voltage variant with potentiometer

Pin

Uv

G nd
Uref

w

G ND

0..10 V

x

7

3
5

4
2

6
8

G ND

V

X extin

1

Pin

U v
G nd

U ref

w

G N D

x

7

3

5

4
2

6
8

G N D

V

X ext in

1

Fig. 7

Fig. 8

Current variant

Pin

Uv

G nd

U ref

w

G N D

x

7

3

5

4
2

6
8

G N D

A

X ext in

4..20 m A

B ürde m ax. 300

1

Fig. 9

The individual pins on the electrical connection are assigned as follows:

Pin num-
ber

Description

Voltage
variant

Current
variant

Cable col-
our

3)

3

7

2

4

1

6

8

5

1

X extin
- with actual value

reader

- without actual value

reader

DC 0 ... 10 V

1)

4 ... 20
mA

-

White
(WH)

-

2

Setpoint value

2)

GND

GND

Brown
(BN)

3

Supply

2)

GND

GND

Green
(GN)

4

Setpoint

DC 0...10 V

4...20 mA

Yellow
(YE)

5

Ref. output

DC 10 V

DC 10 V

Grey (GY)

6

Actual value output

DC 0...10 V

4...20 mA

Pink (PK)

7

Supply voltage

DC 24 V

DC 24 V

Red (RD)

8

Actual value

2)

GND

GND

Blue (BU)

1)

Connect to GND for hardware versions from 1.11.98 (see rating plate).

For older hardware versions: no assignment.

2)

Connected internally

3)

When using the socket with cable type KMPPE-...

Fig. 10

5

Commissioning

1. Supply the MPPE-... with direct current

(supply voltage U

v

= DC 24 V).

2. Supply the MPPE-... with a setpoint sig-

nal.

3. Pressurise the MPPE- with an input pres-

sure higher than the maximum required
output pressure.
A proportional output pressure P

s

is then

set.
Different pressure ranges are assigned to
the setpoint signal range DC 0 ... 10 V
and 4 ... 20 mA depending on the design
(

Fig. 13 and Fig. 14):

Fig. 11

24 VDC

3

7

Fig. 12

4..20mA

0..10V

3

7

2

4

1

6

8

5

Fig. 13

10 [V]
20 [mA]

[bar P]