Maintenance Intervals
Regularly carry out the maintenance work listed in the “maintenance intervals” table.
Regular maintenance prolongs the life of the equipment. It also gives optimum cutting per-
formance and avoids accidents.
Maintenance Work
(See “cleaning and mainte-
nance“)
Before
After
After 1
st
5 Hrs.
After
8 Hrs.
After
50 Hrs. Annual
Work
Check and tighten screws, nuts
and bolts
Check the engine oil level/petrol
level and refill with engine oil/
petrol if required
Clean operating elements / the
area around the silencer
Clean the finger protection
b
Change the engine oil
Replace the air filter
a
Clean/adjust the spark plug
Replace the spark plug
Check the silencer and spark
catcher
b
Clean the air cooling system
a,b
a
Replace more often if there is a high level of dust or heavy dirt
b
See Briggs & Stratton instruction manual