Festo Пропорциональные распределители MPYE Benutzerhandbuch
Seite 15
Advertising

Setpoint specification
as voltage value V
w
as current value I
w
5 V
12 mA
Between 5 V and 0 V
Between 12 mA and 4 mA
Between 5 V and 10 V
Between 12 mA and 20 mA
Flow rate
(idealised)
Change in flow rate
Flow rate blocked
Flow rate rises at outlet 2
Flow rate rises at outlet 4
Connections
All connections closed
Pressurisation: 1
→ 2
Exhaust:
4
→ 5
Pressurisation:
1
→ 4
Exhaust:
2
→ 3
Valve slide motion
Mid-position (unchanged)
Towards inspection window
Away from inspection window
5 V
(12 mA)
Q max.
10 V
(20 mA)
Voltage
(current)
0
(4 mA)
5 V
(12 mA)
Voltage
(current)
Q max.
Mid-position in the
range of the flat zone
of the flow setpoint
diagram (leakage rate).
7
7
Fig. 20
2
7
4
7
5. Pressurise the MPYE-... slowly.
1304f
D/GB 15
Advertising