Mounting, Intended use – VEGA T32.10-11-30 Benutzerhandbuch

Seite 7

Advertising
background image

GB

2383336 12/2008 GB/D

WIKA Operating Instructions Temperature Transmitter T32.10/11/30

7

3.

Intended use

/ 4. Mounting

Shock

DIN IEC 68-2-27 /gN = 30

Salt mist

DIN IEC 68-2-11

Case material

platic, PBT, glass fibre
reinforced

plastic

Ingress protection

Case

Terminals

IP 66 / IP 67
IEC 29 / DIN EN 60 29
IP 00
IEC 29 / DIN EN 60 29

IP 0
IEC 29 / DIN EN 60 29
IP 20
IEC 29 / DIN EN 60 29

For further technical details please refer to WIKA data sheet
TE 32.03.

4. Mounting

4.1 Head mounting (Model T32.1X)
The transmitters for head mounting (model T32.1x) are designed to
be mounted on a measuring insert in a DIN connection head,
form B, with extended mounting space. The connection wires of the
measuring insert must be approx. 0 mm long and insulated.

The T32.10 shall be used with grounded thermometers only!

Mounting example:

3173801.A