Sensor bracket sl-dsm-s-m5/m8-b – Festo SL-DSM-S-M5/M8-B Монтаж Benutzerhandbuch

Seite 2

Advertising
background image

Assembly instructions (en)
743 702 / 2009-02NH

†‡

Sensor bracket
SL-DSM-S-M5/M8-B

Festo AG & Co. KG

Postfach
D-73726 Esslingen
++49/(0)711/347-0
www.festo.com

1. Parts list

13451d_1

1 Sensor plate, left-hand (1x)

SL-DSM-S-…-B-LI

2 Sensor plate, right-hand

(1x)
SL-DSM-S-…-B-RE

3 Washer

(2x)

B2,2

4 Socket head screw (2x)

M2x6

13451d_2

Not included in scope of
delivery:
5 Proximity sensor, inductive

The intended use of the sensor bracket is to fasten inductive proximity
sensors to the swivel module DSM-...-B.

Note

In order to avoid functional faults:
• Please select the appropriate accessories from our catalogue

www.festo.com/catalogue

. Inductive proximity sensors are provided as

follows:

13451d_7

Type of
mounting

Thread

Rated operating
distance S

flush fitting

M5x0.5

0.8 mm

M8x1

1.5 mm


2. Assembly

13451d_3

• Place the sensor plate 1 on

the cushioning mount (A) in
the groove (B).

• Turn the socket head

screw 4 with the washer 3
just lightly at first.

• Fasten the sensor plate 2

on the cushioning mount (C)
accordingly.

13451d_4

• Turn the two proximity sen-

sors 5 just far enough into
the sensor plates 1/2 that
they do not collide with the
stop lever (D)

! Table: Rated

operating distance S.

Note

In order not to damage the screw connection on the sensor plate 1/2
during assembly or adjustment of the proximity sensor 5:
• Be sure to use an open-ended spanner hold (F) ! SW12 to hold the

sensor plate 1/2 while tightening the lock nut (E).

13451d_5

• Turn the stop lever (D) to the

position of the proximity
sensor 5.

• Turn the proximity sensor 5

into the sensor plate until it
operates reliably

! Table:

Rated operating distance S.

• Fasten the lock nut (E) using

spanner (F) while holding the
sensor plate 1/2. Maintain
the permitted tightening
torque

! Operating instruc-

tions of the proximity sensor.


13451d_6

• Position the sensor

plate 1/2 using the
elongated hole so that the
proximity sensor 5 operates
reliably.

• Tighten the socket head

screw 4. Maintain the
permitted tightening torque.


1

3

2

4

5

1

A

B

4

3 2

C

5

5

D

D

5

E

F

1/2

5

1/2

4

0.4 Nm
_ 10%

D

5

1/2

4