Maximising the service life of the DYSR:
If the shock absorber is not used to its full extent, there will be an increase in the
oil leakage.
• Make sure that the shock absorber is operated with an energy utilization of at
least 25% to max. 100%. The recommended range lies between 50 and 80%.
• Make sure that the DYSR is utilized as follows:
0
25
50
80
100
125 %
D
B
B
C
A
A = unfavourable
B = permitted
C = optimum
D = not permitted
Fig. 8
• Take into account the fact that the viscosity of the hydraulic oil diminishes during
operation due to the friction warmth which arises.
The shock absorber can therefore break through after a long period of operation.
Turn the cushioning on the internal hexagon socket
3 in the “+” direction until
the shock absorber no longer strikes hard.
At temperatures below 0 °C:
• Note that the resetting times of the DYSR become longer (approx. 1 … 3 s).
Low temperatures cause an increase in the viscosity of the hydraulic oil.
6
Maintenance and care
• Examine the DYSR for loss of oil after approximately every 1 million loading
cycles. At the same time you should check the cushioning length (s) of the DYSR
(
Fig. 2 and Technical data).
Otherwise the DYSR does not require any maintenance.
7
Dismantling and repairs
• Reduce the amount of waste by using the materials in the DYSR for other pur-
poses (material recycling). The DYSR is filled with hydraulic oil.
Due to the design the hydraulic oil cannot be refilled.
8
Accessories
Note
• Please select the appropriate accessories from our catalogue
www.festo.com/catalogue
9
Technical data
DYSR
8-8
12-12 16-20 20-25 25-40 32-60
Cushioning length (s) (
Fig. 2)
[mm]
8
12
20
25
40
60
Operating mode
Single acting, pushing
Cushioning
Adjustable, force-dependent, hard characteristic curve
Mounting position
Any
Thread
DYSR-…-Y5
M12
M15
M20
M24
M30
M37
DYSR-…-Y5-T
-
M16
M22
M26
-
-
Pitch
DYSR-…-Y5
[mm]
1
1
1.25
1.25
1.5
1.5
DYSR-…-Y5-T
[mm]
-
1
1.5
1.5
-
-
Width across flats
Lock nut
2
DYSR-…-Y5
[mm]
15
19
24
30
36
46
DYSR-…-Y5-T
[mm]
-
19
27
32
-
-
Internal hex
3
[mm]
4
5
5
5
6
6
Impact velocity
[m/s] 0.1 … 3
Product weight
DYSR-…-Y5
[g]
60
105
200
355
715
1355
DYSR-…-Y5-T
[g]
-
120
250
425
-
-
Ambient temperature
[°C]
–10 … +80
Reset time at ambient temperature
[s]
0.2
0.2
0.3
0.3
0.4
0.6
Resetting force F
1
[N]
1.8
4.5
5.4
9
12.5
18
Insertion force F
2
[N]
18
38
66
110
155
175
Max. stop force in end position
[N]
400
900
1600
2500
4000
6400
Max. energy absorption per stroke
1)
[J]
4
10.8
32
62.5
160
384
Max. energy absorption per hour
1)
[kJ]
24
60
100
135
220
330
Max. mass
1)
[kg]
40
90
160
250
400
600
Information on materials
Housing
High-
alloy
steel
Galvanised steel
Piston rod
Hardened steel
Buffer
Poly-
acetal
–
Seals
Nitrile rubber
1)
The specified technical data refers to ambient temperature. At higher temperatures in the 80 °C range,
the max. mass and the max. energy absorption must be reduced by approx. 50 %.
Fig. 9
DYSR
液压缓冲器
中文
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
功能和应用
DYSR 液压缓冲器中装满了液压油。
当负载撞击缓冲器时,液压油通过节流阀被挤出; 撞击动能转化为热能。
通过压缩弹簧的作用使活塞杆复位。
DYSR 设计用于吸收惯性力。 并且缓冲方向仅限于轴向。 在许用负载范围内,
DYSR 也作为止动挡块使用。
2
产品使用条件
注意
操作不当会引发功能故障。
•
请确保始终遵守本章规定。
•
请将本操作说明中各项参数极限值与您使用场合的实际值(例如:力、
频率、质量、温度、速度等)相比较。 只有遵守负载极限值才能使 DYSR
按照相关的安全规程安全运行。
•
请考虑到产品应用地点的环境条件。
•
请注意遵守使用地点的有关规定(例如:同业公会或所在国相关机构)。
•
不要对 DYSR 的原始状态擅自进行任何改动。
•
对于 DYSR-12
…
32,请使用型号为 YSRP
的缓冲器来减轻碰撞声( www.festo.com/catalogue)。
3
安装
当超过最大许用冲击力时:
•
除了液压缓冲器外,还需额外使用止动挡块。
•
在安装 DYSR 时请注意以下几点:
–
确保负载尽可能正向、均匀地撞到外部固定挡块上。
–
确保负载尽可能沿轴向撞到活塞杆 1 上(最大 偏差: ± 3°
Fig. 2
)。
•
按照所选固定方式拧紧锁紧螺母 2。
拧紧时必须遵守下表中的紧固扭矩。
DYSR
8-8
12-12 16-20 20-25 25-40 32-60
2 的紧固扭矩。
[Nm]
5
20
35
60
80
100
Fig. 10
4
调试
•
请注意下列力的允许值:
–
压入力 (F
2
)( Fig. 2和技术数据)
–
复位力 (F
1
)( Fig. 2和技术数据)。
•
压入力 (F
2
) 至少提升至液压缓冲器能完全压入后面的终端位置。
对于前置的外部终端位置,此值应相应地减小。
•
复位力 (F
1
) 可以完全施加在活塞杆上,以使液压缓冲器能够
完全复位(例如:活塞杆完全伸出)。
•
调节液压缓冲器( Fig. 3):将缓冲器上的内六角孔 3 沿 “+”
方向完全拧紧。
•
先用较小的运行速度启动运动部件进行测试。
试运行时:
•
将工作载荷逐步加速至所需运行速度。
请根据载荷大小选定合适的运行速度。
•
沿 “–” 方向拧缓冲器上的内六角孔 3。 理想的终端缓冲效果应该是:
液压缓冲器的活塞杆到达终端位置(止动挡块)时不会发生强烈撞击。
5
操作和运行
如果运行条件改变了:
注意
工作载荷的改变可能会导致部件强烈撞向终端位置(负载峰值)。
•
请重复 DYSR 的调节过程(
调试)。
发生强烈撞击时需要采取以下补救措施:
•
在内六角孔 3 上沿 “+” 方向调节缓冲器或降低冲击速度。
•
检测缓冲行程 (s) ( Fig. 2和技术参数)。
缓冲行程不够表明可能存在较为严重的漏油现象。 此时必须更换 DYSR。