Operating mode of the air-saving function (LS)
If the desired threshold value
1 ( Fig. 4 “Operating mode of the air-saving function”) is reached for
the vacuum, vacuum generation is automatically switched off. Non-return valves prevent the reduction
of the vacuum. Nonetheless, leakage (e. g. rough workpiece surfaces) will slowly reduce the vacuum.
If the pressure drops below the set threshold value
2 vacuum generation is switched on automatically.
A vacuum is generated until the set threshold value
1 is reached again.
Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden:
- VTSA-F-NPT с подключением AS-интерфейса VTSA-F с подключением AS-интерфейса VTSA-F-NPT с многополюсным подключением VTSA-F с многополюсным подключением VTSA-F-NPT с терминалом СРХ VTSA-F с терминалом СРХ VTSA-NPT с подключением AS-интерфейса VTSA с подключением AS-интерфейса VTSA-NPT с многополюсным подключением VTSA с многополюсным подключением VTSA-NPT с терминалом СРХ VTSA с терминалом СРХ Рабочие компоненты к ISO 15407-2