5 quick commissioning with default settings, 5quick commissioning with default settings – Festo Рабочие компоненты для VTIA, ISO 15407-2 Benutzerhandbuch
Seite 50
Advertising

VABF-S4-1-V2B1…
50
Festo – VABF-S4-1-V2B1…-D2 – 1212a English
5
Quick commissioning with default settings
The pressure switch of the vacuum module has the following settings when delivered:
Channel A, air-saving function
•
Switching characteristics:
Threshold value comparator
•
Switching point
–700 mbar
•
Hysteresis:
200 mbar
•
Switching characteristic:
NO (normally open contact)
Channel B, vacuum query
•
Switching characteristics:
Threshold value comparator
•
Switching point
–400 mbar
•
Hysteresis:
5 mbar
•
Switching characteristic:
NO (normally open contact)
If you do not want to use these settings, you can set a switching point for Out A or Out B manually
(
section 6.3.2).
Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden:
- VTSA-F-NPT с подключением AS-интерфейса VTSA-F с подключением AS-интерфейса VTSA-F-NPT с многополюсным подключением VTSA-F с многополюсным подключением VTSA-F-NPT с терминалом СРХ VTSA-F с терминалом СРХ VTSA-NPT с подключением AS-интерфейса VTSA с подключением AS-интерфейса VTSA-NPT с многополюсным подключением VTSA с многополюсным подключением VTSA-NPT с терминалом СРХ VTSA с терминалом СРХ Рабочие компоненты к ISO 15407-2