Malfunction
Remedy
Possible cause
Required vacuum is
not obtained
Insufficient supply of air to the valve
terminal
–
Increase supply pressure
–
Increase supply cross section
–
Install an additional supply plate
directly next to the vacuum
module, optionally create a
separate pressure zone, see
manual VTSA/VTSA-F
Soft-start valve installed on the valve
terminal
If the valve terminal is pressurised,
first send an electrical release
signal (14) to deactivate vacuum
generation. Only revert to vacuum
generation after full operating
pressure of the valve terminal has
built up (12).
Vacuum module does
not revert to the
air-saving function
Insufficient supply of air to the valve
terminal
–
Increase supply pressure
–
Increase supply cross section
–
Install an additional supply plate
directly next to the vacuum
module, optionally create a
separate pressure zone, see
manual VTSA/VTSA-F.
Switching thresholds or hysteresis
set incorrectly
Correct switching thresholds and/or
hysteresis
Channel A and/or B set as N/C
contact (NC)
Set channel A and B as N/O contact
(NO)
Channel A and/or B set as window
comparator
Set channel A and B as threshold
value comparator
Er01
1)
Pressure sensor defective
Send device to Festo
Er09
1)
Value below measuring range
with In A
Maintain permitted measuring range.
If the permitted maximum values are
exceeded, the pressure sensor must
be replaced. Send device to Festo.
Er10
1)
Measuring range exceeded
with In A
Er11
1)
Value below measuring range with
In B
Er12
1)
Measuring range exceeded
with In B
Er17
2)3)
Undervoltage
Maintain operating voltage
1)
7-segment display flashes. Error display in the SHOW mode (
section 6.2 “SHOW mode”).
2)
7-segment display flashes. The smallest current error number is shown.
3)
Outputs are reset automatically (0-signal).
Tab. 8
Troubleshooting
- VTSA-F-NPT с подключением AS-интерфейса VTSA-F с подключением AS-интерфейса VTSA-F-NPT с многополюсным подключением VTSA-F с многополюсным подключением VTSA-F-NPT с терминалом СРХ VTSA-F с терминалом СРХ VTSA-NPT с подключением AS-интерфейса VTSA с подключением AS-интерфейса VTSA-NPT с многополюсным подключением VTSA с многополюсным подключением VTSA-NPT с терминалом СРХ VTSA с терминалом СРХ Рабочие компоненты к ISO 15407-2