Festo DRQD-40 ... 50-... Benutzerhandbuch
Seite 66

DRQD−...
Festo DRQD−... 0907e English
66
1. Slowly pressurise both supply ports of the semi−rotary drive DRQD. For slow
start−up pressurisation use safety start−up valve type HEL.
2. Screw the flow control screw of the GRLZ at the mid−position module:
ć completely in
ć and then open with one rotation.
3. Pressurise the mid−position module. The semi−rotary drive moves to the preset
mid−position.
4. Vent the mid−position module.
5. Start a test run at low rotational frequency.
Type
DRQD−...
Diameter
16
20
Cushioning
YSRJ *)
PPVJ
YSRJ *)
PPVJ
Rotation angle
90
180
90
180
90
180
90
180
Possible cycle time [sec.]
(rotating from end position
to mid−position at 6 bar)
0.2
0.26
0.2
0.23
0.22
0.41
0.22
0.31
Diameter
25
32
Cushioning
YSRJ *)
PPVJ
YSRJ *)
PPVJ
Rotation angle
90
180
90
180
90
180
90
180
Possible cycle time [sec.]
(rotating from end position
to mid−position at 6 bar)
0.18
0.20
0.17
0.22
0.21
0.24
0.19
0.24
Diameter
40
50
Cushioning
YSRJ
PPVJ
YSRJ
PPVJ
Rotation angle
90
180
90
180
90
180
90
180
Possible cycle time [sec.]
(rotating from end position
to mid−position at 6 bar)
0.47
1.10
0.0
0.21
0.35
0.99
0.18
0.35
*) The maximum permissible mass moment of inertia of the functional variants
DRQD−...−YSRJ exceeds the permissible load of the mid−position (only mass moment
of inertia of DRQD−...−PPVJ permissible).
Fig. 53: Possible cycle times for checking in test run