Festo DRQD-40 ... 50-... Benutzerhandbuch

Seite 66

Advertising
background image

DRQD−...

Festo DRQD−... 0907e English

66

1. Slowly pressurise both supply ports of the semi−rotary drive DRQD. For slow

start−up pressurisation use safety start−up valve type HEL.

2. Screw the flow control screw of the GRLZ at the mid−position module:

ć completely in
ć and then open with one rotation.

3. Pressurise the mid−position module. The semi−rotary drive moves to the preset

mid−position.

4. Vent the mid−position module.

5. Start a test run at low rotational frequency.

Type

DRQD−...

Diameter

16

20

Cushioning

YSRJ *)

PPVJ

YSRJ *)

PPVJ

Rotation angle

90

180

90

180

90

180

90

180

Possible cycle time [sec.]
(rotating from end position
to mid−position at 6 bar)

0.2

0.26

0.2

0.23

0.22

0.41

0.22

0.31

Diameter

25

32

Cushioning

YSRJ *)

PPVJ

YSRJ *)

PPVJ

Rotation angle

90

180

90

180

90

180

90

180

Possible cycle time [sec.]
(rotating from end position
to mid−position at 6 bar)

0.18

0.20

0.17

0.22

0.21

0.24

0.19

0.24

Diameter

40

50

Cushioning

YSRJ

PPVJ

YSRJ

PPVJ

Rotation angle

90

180

90

180

90

180

90

180

Possible cycle time [sec.]
(rotating from end position
to mid−position at 6 bar)

0.47

1.10

0.0

0.21

0.35

0.99

0.18

0.35

*) The maximum permissible mass moment of inertia of the functional variants

DRQD−...−YSRJ exceeds the permissible load of the mid−position (only mass moment
of inertia of DRQD−...−PPVJ permissible).

Fig. 53: Possible cycle times for checking in test run

Advertising
Dieses Handbuch ist für die folgenden Produkte bezogen werden: