9 eliminating faults, Eliminating faults, 9eliminating faults – Festo Генератор вакуума OVEM, дюймовый Benutzerhandbuch
Seite 101

OVEM
Festo ć OVEM ć 1004b English
101
9
Eliminating faults
Fault
Possible cause
Remedy
Work item does not
loosen from suction
cup
Vacuum builds up when large suction
cups lift quickly
Ĉ Increase duration and intensity of
reject pulse
Ĉ Lift suction cup more slowly from
work item
Ĉ Set the reject pulse actively when
the suction cup lifts
The tubing used between suction cup
and vacuum generator has the wrong
dimensions (tubing is too long and/or
internal diameter too small)
Replace tubing
Tubing requirements è chapter 4.2
Flow control screw is closed
Open flow control screw
No display
Supply voltage not applied or no
permitted operating voltage
Switch on supply voltage / maintain
permitted operating voltage range
Electrical connections swapped
(incorrect polarity)
Connect the device as per circuit
diagram
Device defective
Exchange device
Incomplete display
Display defective
Exchange device
Incorrect pressure
display
Pneumatic connections swapped
Connect tubing in accordance with
section Pneumatic installation"
p y
Device operated with non−permitted
medium
Replace the device and operate only
with compressed air
Outputs do not
switch according to
Short circuit/overload at relevant
output
Eliminate short circuit/overload
g
settings
Device defective
Exchange device
Settings cannot be
edited (Lock" in
the display)
Access protection active
Enter security code
(if security code is lost, reset device to
factory setting è chapter 7.3)
[min] [max] flash
synchronously
Diagnostic stage 1 active
Tab. 15:
LCD display and
[min] [max] flash
Diagnostic stage 2 active
Tab. 15:
Display flashes and
ErXX is shown
Diagnostic stage 3 active
Tab. 15:
[Option] flashes
Settings during teaching incorrect,
e.g. hysteresis with air−save function
<Ă100 mbar
Teach again, reset hysteresis
Tab. 16: Eliminating faults