2 pneumatic installation, 3 electrical installation, Pneumatic installation – Festo Генератор вакуума OVEM, дюймовый Benutzerhandbuch
Seite 74: Electrical installation

OVEM
74
Festo ć OVEM ć 1004b English
4.2
Pneumatic installation
· Connect the QS connections (−QS, −QO, −PL, −PO) with suitable tubing.
We recommend that tubing type PUN be used.
· When selecting the tubing for connecting the vacuum generator with thread connections (−GN, −GO),
note the Tab. 7: minimum internal diameterfor tubing.
Type
OVEM−05
GN/GO
OVEM−07
GN/GO
OVEM−10
GN/GO
OVEM−14
GN/GO
Tube length
< 0.5 m
< 2 m
< 0.5 m
< 2 m
< 0.5 m
< 2 m
< 0.5 m
< 2 m
Minimum internal tubing diameter [mm]
Connection 1
Compressed air
1
2
1.5
2
2
3
3
4
Connection 2
Vacuum
2
3
3
4
4
5
5.5
6
Connection 3
Exhaust
2
3
3
4
4
5
5.5
6
Tab. 7: Minimum internal tubing diameter
· In the case of OVEM−07/10/14, you can if necesssary extend the silencer with a silencer extension
element
(è
Accessories).
4.3
Electrical installation
Warning
· Use only power units which guarantee reliable electrical isolation of the operating
voltage as per IEC/DIN EN 60204−1. Take into account also the general requirements
for PELV circuits as per IEC/DIN EN 60204−1.
Note
Long signal cables reduce the immunity to interference.
· Make sure that the signal cables are not longer than 30 m.
· Make sure that the operating voltage supply is 24 V DC ±15 %.
The solenoid coils and electric components will be damaged if the maximum permitted switching
voltage is exceeded.
· Connect the cable socket to plug
aD.
· Connect the vacuum generator as shown in Tab. 8: