1 symbolical lcd display, Symbolical lcd display – Festo Генератор вакуума OVEM, дюймовый Benutzerhandbuch
Seite 80

OVEM
80
Festo ć OVEM ć 1004b English
6.1
Symbolical LCD display
Display
Icon
Description
Modes
p y
p
RU
N
SHOW
EDIT
TEA
CH
Switching output set/not set
X
Switching output selected/not selected
X X X
Segment
Switch
There is a signal at the switch input
X
input In
lights up
Manual override active
X
Threshold value comparator
X X
Window comparator
X X
[msec]
Reject pulse (time setting)
X X
[SP]
Switching point
X X
[SP] [min]
Lower switching point (switching point ć min.)
X X
[SP] [max]
Upper switching point (switching point ć max.)
X X
[SP] [max]
Diagnosis: Limit value evacuation time
X X
[SP] [max]
Diagnosis: Limit value pressurization time
X X
[HY]
Hysteresis
X X
[NO]
Switching character. of normally open contact
X X
[NC]
Switching character. of normally closed contact
X X
[min] / [max]
Extreme values: min./max. measured input
value (In A1)
1)
X
[min] [msec]
Min. evacuation time
X
[max] [msec]
Min. evacuation time
X
[min] [msec]
Min. pressurization time
X
[max] [msec]
Max. pressurization time
X
[Teach]
Teach mode active
X
[Option]
Air−save function active
X X X