12 technical specifications, Technical specifications – Festo Генератор вакуума OVEM, дюймовый Benutzerhandbuch
Seite 103

OVEM
Festo ć OVEM ć 1004b English
103
12
Technical specifications
Type
OVEM−05
OVEM−07/−10
OVEM−14
Operating pressure
[bar]
−QS, −GN, −PLā: 2
Ū 6
p
g p
[
]
−QO, −GO, −PO: 2
Ū 8
Operating medium
Dried, filtered and unlubricated compressed air
Ambient temperature
[°C]
0
Ū 50
Media temperature
[°C]
0
Ū 50
Operating voltage range
[V DC]
24 ±15 %
Idle current
[mA]
< 70
Coil characteristic values 24 VDC
[W]
Low−current phase: 0.3
[ ]
High−current phase: 2.55
Time till current reduction
[ms]
< 80
Ready−state delay
[ms]
< 500
Switch outputs
Ĉ Max. output current
[mA]
100
Ĉ Voltage drop
[V]
Ţ 1.5
Ĉ Capacitive load max. DC
[nF]
Ţ 100
Ĉ Inactive time
[ms]
< 10
Ţ 20
Protective functions
Ĉ Inductive protective circuit
Adapted to MZ, MY, ME coils
Ĉ Protection against short circuit
Yes
Ĉ Protection against overloading
Yes
Protection against polarity reversal
For all electrical connections
Protection class
IP65
Protection type
3
Interference immunity
See declaration of conformity (www.festo.com)
Interference emission
See declaration of conformity (www.festo.com)
Vibration resistance
As per DIN/IEC 68/EN 60068 part 2−6:
0.35 mm path at 10
Ū 60 Hz,
5 g acceleration at 60
Ū 150 Hz
Shock resistance
As per DIN/IEC 68/EN 60068 part 2−27:
30 g acceleration at 11 ms duration (half sine)
Max. permitted signal line length
[m]
30
Overload pressure at vacuum
connection
[bar]
Ţ 5
Pressure measuring range
[bar]
−1
Ū 0
Accuracy
[% FS]
±3
Threshold value setting range
[bar]
−0.999
Ū 0 (recommended work range: −0.95 Ū −0.05)