Evacuation and pressurization times – Festo Генератор вакуума OVEM, дюймовый Benutzerhandbuch
Seite 90

OVEM
90
Festo ć OVEM ć 1004b English
3. Set the desired time (in ms) with the UP/DOWN button.
The value 0 corresponds to OFF, the reject pulse is switched off.
4. Press the EDIT button in order to confirm the value set.
è
FORC lights up. The submenu for the function electric manual override is active.
Electric manual override
5. Actuate the solenoid valves via the electronic circuit as follows:
A−button: for solenoid valve control (vacuum ON/OFF)
B−button: for solenoid valve ejector pulse.
6. Press the EDIT button in order to conclude the submenu.
è
The vacuum generator is in the RUN mode.
6.3.4
[SPEC] ć air−save function option (LS option), set security code, evacuation and
pressurization times
L
L
L
L
Fig. 16: Special menu (SPEC) (menu structure EDIT mode è Fig. 24: )
The vacuum generator is in the EDIT mode and [Out A] flashes.
1. Press the A−button until the menu (SPEC) is selected.
è
[SPEC] flashes.
2. Press the EDIT button in order to confirm the selection.
è
[Option] flashes.
3. Select the desired LS option with the UP/DOWN button (ON: LS active; OFF: LS inactive).
4. Press the EDIT button in order to confirm the selection.
è
[Lock] flashes.
5. Set the desired security code with the UP/DOWN button (OFF = no protection).
Tip: Keep the security code in a safe place. If you forget the security code è chapter 7.3.