Teach the switching variables
Note
The sequence for setting the switch outputs Out A (A button) and Out B (B button) is the
same. The sequence is described below taking the example of switch output Out A.
Fig. 17: Teach switching variables in te example of Out A (menu structure TEACH mode è Fig. 25: )
1. Switch on the operating voltage.
è
The vacuum generator is in the RUN mode.
2. Set the first vacuum (TP1) (e.g. object grasped or object not grasped, the sequence is optional)
3. Press first the A−button (UP button) and then also the EDIT button.
è
[A] and [TeachIn] flash and the measured value is accepted as Teach point (TP1) for Out A or
flashes if the security lock is active [Lock] (è chapter 6.4.4).
4. Repeat steps 2 and 3 for the second teach point (TP2).
è
The second teach point (TP2) will be accepted and the new switching point (SP) or the switching
points (SP
min
and SP
max
) become valid.
The vacuum generator switches to the RUN mode.
Note
The setting for the hysteresis is adapted. It can be modified via the EDIT mode
(è chapter 6.3 EDIT mode). Factory setting è chapter 5