Fronius String Control 100/12 Benutzerhandbuch
Seite 76

74
Connecting Data Communication Cable to the Fro-
nius String Control 100/12
Connection Op-
tions
There are two options for connecting the Fronius String Control 100/12 to Solar Net:
-
via pre-assembled data communication cables with RJ 45 plugs
Cable recommendation:
cable size CAT 5, 1:1 cable
-
via multi-core data communication cables
max. cable cross section 2.5 mm²
RJ 45 connections
Spring terminals for connecting multi-core data com-
munication cables
Additional Insula-
tion for Data
Communication
Cables
IMPORTANT! A silicone tube is part of the scope of supply for the Fronius String Control
100/12 for additional data communication cable insulation.
When laying the data communication cables on the inside of the Fronius String Control
100/12, the data communication cables must be fed through the silicone tube.